Thermocouple Cable - Kapton® Insulated Twisted Pair
Single Pair Thermocouple Cables
|
||||||
Kapton® Laid Flat Pair
One pair of stranded conductors Kapton insulated. Pair twisted. |
Kapton® Laid Flat Pair
One pair of solid conductors Kapton insulated. Pair twisted. |
|||||
Stock Number | B02 | B09 | ||||
Conductor Style | Stranded | Solid | ||||
No. of Strands / Strand Diameter (mm) | 7/0.2 | 1/0.5 | ||||
Total Area (mm2) | 0.22 | 0.2 | ||||
Total AWG (S = Stranded) | 24S | 24 | ||||
Insulation | Kapton | Kapton | ||||
Number of Pairs | 1 | 1 | ||||
Laid Flat or Twisted | Twisted | Twisted | ||||
Screen | No | No | ||||
Insulation | Kapton | Kapton | ||||
Insulation Rating (ºC) |
Continuous | -75 to +285 | -75 to +285 | |||
Short Term | +400 | +400 | ||||
Colour Coding | Yes | Yes | ||||
Physical Properties |
Abrasion Resistance | Very Good | Very Good | |||
Moisture Resistance | Fair | Fair | ||||
Typical Weight (Kg/100m) excl reel |
<1 | <1 | ||||
Diameter under Armour (mm) | — | — | ||||
Diameter over Armour (mm) | — | — | ||||
Overall Diameter | 1.6 | 1.4 | ||||
Popular Order Codes | B02JX, B02TX |
B09JX, B09KX, B09TX |
||||
Notes All dimensions are approximate |
Rejects electromagnetic interference.. |
Rejects electromagnetic interference. |