Products

Thermocouple with Terminal Entry Gland

Mineral Insulated Thermocouples

Related Products

Thermocouple Cables

Related Products

Miniature Socket

Related Products

Standard Socket

Related Products

Miniature Plug

Related Products

Standard Plug
  • High integrity construction suited to arduous operating conditions at temperatures from -200ºC to +1250ºC (The maximum operating temperature is dependant on diameter and environmental factors, further guidance is available here.)
  • Custom built to your specification and terminated in either a brass or St./Steel 16mm ISO x 1mm gland with a choice of temperature ratings. Supplied with either short tails as shown or a longer extension lead
  • Alternatively, we have a large range of sensors available to buy online in various diameters and lengths
  • High accuracy and stability maintained throughout the operating life of the sensor
  • Fast response and high insulation resistance
  • Available in thermocouple types K, T, J, N, E, R, S & B with sheath diameters from 1.0mm to 8.0mm and lengths from a few millimetres to 200 metres or more dependent on the sheath diameter selected

Thermocouple Enquiry Form

1a. Thermocouple Type
1b. Tolerance Class
2. Sheath Material
3. Sheath Diameter
4. Sheath Length

 mm
5. Types of Sensing Junction

Illustration Select
INSULATED Junction
GROUNDED Junction
EXPOSED Junction
Duplex Element Required? (please tick box)
Triplex Element Required? (please tick box)
6. Pot Seal Style

Illustration Select
Brass Compression Gland Seal 16mm ISO x 1.5mm - FIXED
(sheath diameters 1mm to 8mm)
St./St. Compression Gland Seal 16mm ISO x 1.5mm - FIXED
(sheath diameters 1mm to 8mm)

End Seal Temperature Rating:

7. Extension Leads

Illustration Select
PVC (rated to 105ºC)
PFA (rated to 250ºC)
Fibreglass (rated to 480ºC)
Fibreglass with St./St. Overbraid (rated to 480ºC)
Colour Codes available to ANSI MC96.1
Please enter Cable length in metres

 mtrs
8. Optional Compression Fitting
9. Optional Connector

Illustration Select
Standard 2 pin (round) Plug
Miniature 2 pin (flat) Plug
Standard 2 pin (round) Socket
Miniature 2 pin (flat) Socket
Colour Codes available to ANSI MC96.1

Connector Temperature Rating:

10. Quantity Required

Contact Details

Company Name


Your Name


Email


Telephone


Additional Information

If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  

BACK TO TOP
Products

Contact Us

About TC

FREE Guide

Privacy Policy

Terms and Conditions

Sitemap
FREE Wallchart Guide

Join over 500,000 engineers and buyers who have already received our FREE 74 page A3 Guide to Thermocouple and Resistance Thermometry

Company Name
  Address 1
Your Name
  Address 2
Title / Dept.
  County / Region / State
Email
  Postcode / ZIP Code
Telephone
  Country
Company Name
Your Name
Title / Dept.
Address 1
Address 2
County / Region / State
Postcode / ZIPCode
Country
Email
Telephone

We will only ever use the information you provide to occasionally contact you regarding our products and we will never disclose your details to a third party. Our privacy policy can be viewed here



I agree to the terms and conditions listed in the Privacy Policy

View our ISO 90001/2008 Certficate
View our ISO 90001/2008 Certficate




Thermocouple Sensors
Mineral Insulated Thermocouples
Thermocouples with Mini Plug
Thermocouples with Terminal Head
Thermocouples with Cable
High Temperature Thermocouples
General Purpose Thermocouples
IECEx/ATEX Thermocouple Sensors
Ceramic Thermocouple Sensors
Fast Response Thermocouple Sensors
Autoclave Thermocouple Sensors
Surface Measurement Thermocouple Sensors
FEP Insulated Thermocouple

Platinum Resistance Thermometers
Mineral Insulated RTD Pt100 Sensors
Rigid Stem RTD Pt100 Sensors
Hand Held RTD Pt100 Sensors
Surface Measurement RTD Pt100 Sensors
RTD Pt100 Sensors with Cable
RTD Pt100 Sensors with Mini Plug
Autoclave RTD Pt100 Sensors
RTD Pt100 with Terminal Head
IECEx/ATEX Platinum Resistance Thermometers
Fast Response RTD Pt100 Sensors
Air Temperature RTD Pt100 Sensors
Magnetic RTD Pt100 Sensors
Cable
PVC Single Pair Thermocouple Cable
PFA Single Pair Thermocouple Cable
Fibreglass Single Pair Thermocouple Cable
PVC Multipair Thermocouple Cable
PFA Multipair Thermocouple Cable
Fibreglass Multipair Thermocouple Cable
PVC RTD Pt100 Cable
PFA RTD Pt100 Cable
Fibreglass RTD Pt100 Cable

Miniature Thermocouple Connectors
Mini Thermocouple Connectors – 220ºC Rated
Mini Thermocouple Connectors – 350ºC Rated
Mini Thermocouple Connectors – 650ºC Rated
Mini Thermocouple Connector Accessories
Mini Thermocouple Connector Panels
Mini Three Pin Connectors

Standard Thermocouple Connectors
Standard Thermocouple Connectors – 220ºC
Standard Thermocouple Connectors – 350ºC Rated
Standard Thermocouple Connectors – 650ºC Rated
Standard Thermocouple Connector Accessories
Standard Thermocouple Connector Panels
Standard Three Pin Connectors
Instrumentation
Hand Held Indicators
Panel Indicators
Temperature Transmitters
Temperature Controllers
Temperature Calibrators
Chart Recorders
Multi Channel Indicator
DIN Rail Mounted Transmitters
Head Mounted Transmitters
IECEx/ATEX Rated Transmitters
Dry Block Calibrator
Temperature Dataloggers

Temperature Accessories
Compression Fittings
Pressure and Vacuum Feedthroughs
IECEx/ATEX Compression Fittings

Calibration
Calibration Services

Pressure
Pressure Gauges
Pressure Transmitters


© 1998- TC Measurement & Control Pty Ltd, PO Box 7777, Oakleigh, VIC 3166, Australia
Tel.: 03 9543 8433, Fax: 03 9543 8466, Email: info@tcaus.com.au







>
1 Thermocouple Type Temperature Range (continuous) Temperature Range
(short term)
KNickel Chromium vs
Nickel Aluminium
0°C to +1100°C -180°C to +1350°C
T Copper vs Constantan -185°C to +300°C -250°C to +400°C
J Iron vs Constantan +20°C to +700°C -180°C to +750°C
N Nicrosil vs Nisil 0°C to +1100°C -270°C to +1300°C
E Nickel Chromium vs Constantan 0°C to +800°C -40°C to +900°C
R Platinum - 13% Rhodium vs
Platinum
0°C to +1600°C -50°C to +1700°C
S Platinum - 10% Rhodium vs
Platinum
0°C to +1550°C -50°C to +1750°C
B Platinum - 30% Rhodium vs
Platinum 6% Rhodium
+100°C to +1600°C +100°C to +1820°C
Temperature ranges refer to the thermocouple type.
The temperature range of the sensor may deviate from the above,
please refer to the product description for more details
2 Sheath Material Max.
Temperature
Standard Sheath Materials
321

321 Stainless Steel

800°C
316L

316L Stainless Steel

800°C
310 310 Stainless Steel 1100°C
600 Inconel 600 1100°C
Specialized Sheath Materials
601 Inconel 601 1175°C
800 Incoloy 800 1100°C
825 Incoloy 825 1100°C
114 Nicrotherm DTM 1250°C
446 AISI 446 1150°C
156 Hastelloy X 1220°C
276 Hastelloy 276 1100°C
160 Haynes 160 1200°C
P10R Platinum 10% Rhodium 1400°C
* 5.5mm diameter is a thick wall heavy duty construction

INSULATED
Hot junction insulated from sheath. Gives floating output with typical insulation resistance in excess of 100 megohms

GROUNDED
Hot junction welded to sheath tip giving earthed output and faster response to temperature changes

EXPOSED
Fastest response mainly for the measurement of air temperature in ducts. Restricted to a maximum operating temperature of 600ºC


Assemblies with pot seals are supplied with short tails as shown. However, where leads are several metres or more long, it is more suitable to have an overall sheathed cable. We recommend the following cables, which are 7/0.2mm, laid flat and overall sheathed constructions. Other cables are available, please contact us for details.