Products

Type R Thermocouple - Technical Information



Type R - Platinum-13% Rhodium vs Platinum, IEC 60584-1

Thermocouple Type R is similar to the Type S combination, this thermocouple has the advantage of slightly higher output and improved stability. In general Type R thermocouples are preferred over Type S, and applications covered are broadly identical.

Type R Thermocouples - Typical Constructions and Styles

Type R Mineral Insulated
Thermocouples
Mineral Insulated Type R ThermocouplesRugged sensors, ideal for most applications. Vast choice of terminations e.g. pot seals, cables, connectors, heads etc.
Type R Thermocouples for use in Vacuum Applications Type R Thermocouples for vacuum use Ceramic sheathed calibrated thermocouples designed specifically in vacuum furnace applications with very low leak rates Type R Miniature
Thermocouples
iniature Type R ThermocouplesIdeal for precision temperature measurements where minimal displacement and a fast response is required.
Type R Heavy Duty
Thermocouples
Heavy Duty Type R ThermocouplesFor industrial applications such as furnaces, kilns, ovens, boliers, flues etc. Many types of sheath material available.
ATEX/IECEx Approved
Type R Thermocouples
ATEX Approved Type R ThermocouplesA large range of thermocouples with a variety of terminations such as pot seal, terminal heads etc.

Type R - Technical Data

Conductor Combination Approximate generated
EMF change in µV
per ºC change
(referenced to 0ºC) at:
Approximate Working
Temperature Range
Thermocouple Output Tolerances
to IEC 60584-1
+ Leg - Leg 100ºC 500ºC 1000ºC Continuous Short Term Type Class 1 Class 2 Class 3
PLATINUM - 13% RHODIUM
PLATINUM
8 10 13 0 to +1600ºC -50 to +1700ºC Temperature Range
Tolerance Value
Temperature Range
Tolerance Value
0°C to +1100°C
±1.0°C
1100°C to 1600°C
±(1 +0.003 (t ⋅ 1100)°C
0°C to +600°C
±1.5°C
600°C to 1600°C
±0.0025 ⋅ |t|



1. The tolerance is expressed either as a deviation in degrees Celsius or as a function of the actual temperature.
2. Thermocouple materials are normally supplied to meet the tolerances specified in the table for temperatures above –40 deg C. These materials however, may not fall within the tolerances for low temperatures given under Class 3 for Types T, E and K thermocouples. If thermocouples are required to meet limits of Class 3, as well as those of Class 1 and/or Class 2, the purchaser should state this, as selection of materials is usually required.

Cable Colour Codes for R Type Thermocouples

ANSI MC96.1 IEC 60584-3 Redundant national colour coding for thermocouple cables
BS 1843DIN 43714NFC 42324
IEC60584-3 Type R ThermocoupleANSI MC96.1 Type R ThermocoupleBS1843 Type R Thermocouple
Free Guide to Thermocouple and Resistance Thermometry

BACK TO TOP
Products

Contact Us

About TC

FREE Guide

Privacy Policy

Terms and Conditions

Sitemap
FREE Wallchart Guide

Join over 500,000 engineers and buyers who have already received our FREE 74 page A3 Guide to Thermocouple and Resistance Thermometry

Company Name
  Address 1
Your Name
  Address 2
Title / Dept.
  County / Region / State
Email
  Postcode / ZIP Code
Telephone
  Country
Company Name
Your Name
Title / Dept.
Address 1
Address 2
County / Region / State
Postcode / ZIPCode
Country
Email
Telephone

We will only ever use the information you provide to occasionally contact you regarding our products and we will never disclose your details to a third party. Our privacy policy can be viewed here



I agree to the terms and conditions listed in the Privacy Policy

View our ISO 90001/2008 Certficate
View our ISO 90001/2008 Certficate




Thermocouple Sensors
Mineral Insulated Thermocouples
Thermocouples with Mini Plug
Thermocouples with Terminal Head
Thermocouples with Cable
High Temperature Thermocouples
General Purpose Thermocouples
IECEx/ATEX Thermocouple Sensors
Ceramic Thermocouple Sensors
Fast Response Thermocouple Sensors
Autoclave Thermocouple Sensors
Surface Measurement Thermocouple Sensors
FEP Insulated Thermocouple

Platinum Resistance Thermometers
Mineral Insulated RTD Pt100 Sensors
Rigid Stem RTD Pt100 Sensors
Hand Held RTD Pt100 Sensors
Surface Measurement RTD Pt100 Sensors
RTD Pt100 Sensors with Cable
RTD Pt100 Sensors with Mini Plug
Autoclave RTD Pt100 Sensors
RTD Pt100 with Terminal Head
IECEx/ATEX Platinum Resistance Thermometers
Fast Response RTD Pt100 Sensors
Air Temperature RTD Pt100 Sensors
Magnetic RTD Pt100 Sensors
Cable
PVC Single Pair Thermocouple Cable
PFA Single Pair Thermocouple Cable
Fibreglass Single Pair Thermocouple Cable
PVC Multipair Thermocouple Cable
PFA Multipair Thermocouple Cable
Fibreglass Multipair Thermocouple Cable
PVC RTD Pt100 Cable
PFA RTD Pt100 Cable
Fibreglass RTD Pt100 Cable

Miniature Thermocouple Connectors
Mini Thermocouple Connectors – 220ºC Rated
Mini Thermocouple Connectors – 350ºC Rated
Mini Thermocouple Connectors – 650ºC Rated
Mini Thermocouple Connector Accessories
Mini Thermocouple Connector Panels
Mini Three Pin Connectors

Standard Thermocouple Connectors
Standard Thermocouple Connectors – 220ºC
Standard Thermocouple Connectors – 350ºC Rated
Standard Thermocouple Connectors – 650ºC Rated
Standard Thermocouple Connector Accessories
Standard Thermocouple Connector Panels
Standard Three Pin Connectors
Instrumentation
Hand Held Indicators
Panel Indicators
Temperature Transmitters
Temperature Controllers
Temperature Calibrators
Chart Recorders
Multi Channel Indicator
DIN Rail Mounted Transmitters
Head Mounted Transmitters
IECEx/ATEX Rated Transmitters
Dry Block Calibrator
Temperature Dataloggers

Temperature Accessories
Compression Fittings
Pressure and Vacuum Feedthroughs
IECEx/ATEX Compression Fittings

Calibration
Calibration Services

Pressure
Pressure Gauges
Pressure Transmitters


© 1998- TC Measurement & Control Pty Ltd, PO Box 7777, Oakleigh, VIC 3166, Australia
Tel.: 03 9543 8433, Fax: 03 9543 8466, Email: info@tcaus.com.au